Life sciences · Preprint
arXiv · November 5, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Robot-mediated rehabilitation has the potential to deliver high-intensity, individualized therapy, but existing systems (which have not consistently improved outcomes) typically prescribe kinematic trajectories rather than explicitly targeting the neuromotor activations thought to support recovery. To address this gap, and ultimately enable activation-optimizing rehabilitation robot behavior, we present a personalizable transformer-based model mapping individuals' muscle activations (as measured via surface electromyography) to prescribed contact force trajectories when interacting with an end-effector rehabilitation robot. The model uses a transformer encoder-decoder leveraging rotary positional embeddings (RoPE) to generate a latent representation of trajectory-relevant and user-specific neuromotor factors, and augments trajectory prediction with flow matching to produce a distribution over plausible prescriptions biased toward the training distribution. Using data from 16 healthy participants completing 15 isometric trajectory tracking tasks, we evaluate generalization across held-out tasks and users, as well as the feasibility of user-specific fine-tuning within a therapy-session timescale. The model achieves mean trajectory prediction errors of <8% on held out tasks and users, with effectively instantaneous deterministic inference and sub-second sampling of trajectory distributions. An initial test using the model during live rehabilitation tasks demonstrates that, on average, participants reach the target neuromotor activations with just 15% error accumulated throughout the task. These results provide a proof of concept for data-driven, activation-targeted trajectory prescription in robot-mediated rehabilitation and establish a foundation for future validation in clinical populations. Data and code have been open-sourced as part of the OpenRobotRehab project on SimTK.