Life sciences · Preprint
arXiv · October 23, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Pipelines that combine large language models (LLMs) with static analysis let the model consume the analyser's output as evidence, but whether the model distinguishes true from false evidence, and whether its scrutiny depends on what the evidence claims, has not been measured. We built an intraprocedural analyser for C/C++ that produces proof obligations and audited vulnerable and patched functions from PrimeVul under six evidence conditions that differ only in the notes, including fabricated assurances that a missing check exists and fabricated alarms that an added check is missing. The study covers 916 pairs in four disjoint sets, eleven model configurations from four vendors and 16,572 audits; no model is trained or fine-tuned. True evidence barely improved accuracy (+0.02). False evidence acted asymmetrically: relative to true notes about the same operations, false assurances lowered the detection of real vulnerabilities by up to 19 points, whereas false alarms never significantly lowered accuracy and were disputed far more often. An internally registered replication on seven new models confirmed that false assurances move verdicts towards their claim more than false alarms do (mean asymmetry +0.16, 95% CI +0.10 to +0.24). Instructions in the audit prompt did not reliably reduce deference; the best one failed to replicate. Verifying each claim in a separate call and showing the refuted claims raised accuracy under false assurances by 12 points in a pre-specified test (p=0.002) without loss under true evidence; for a second model the gain was smaller and not significant. Pipelines should therefore verify a tool's guarantees before the model relies on them, and studies should measure deference in a direction-aware way.