Life sciences · Preprint
arXiv · October 9, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Softmax-based multimodal emotion recognition methods often assign high confidence even when sensor data are corrupted or contradictory, for example when facial expressions suggest positive valence while vocal prosody indicates negative arousal. We present an Evidential Multimodal Transformer with Dempster-Shafer Fusion (EMT-DS) that addresses this problem through formal uncertainty quantification. EMT-DS models predictions as Subjective Opinions (Dirichlet distributions), separating epistemic uncertainty (lack of evidence) from aleatoric uncertainty (sensor noise). Modality-specific transformer encoders produce belief mass distributions that are fused with Dempster's Rule of Combination, which normalizes the joint belief mass by a conflict coefficient 1/(1-c), so that contradictory evidence is explicitly quantified as conflict and the fused prediction becomes diffuse rather than being forced into an unjustified consensus. Under subject-independent and speaker-independent evaluation on four benchmarks, EMT-DS achieves 84.3% accuracy on IEMOCAP versus 81.7% for the best baseline (p < 0.01), 82.4% on DEAP under leave-one-subject-out evaluation versus 78.1%, and 96.8% on the highly imbalanced KEMDy20, and it improves accuracy on CMU-MOSEI by 2.4 points over the strongest evidential baseline. In controlled ablation, it reduces Expected Calibration Error from 0.153 (softmax transformer) to 0.042. It maintains 71.2% accuracy under severe Gaussian noise on audio features (sigma = 1.0), where attention baselines drop to 45.3%, and degrades gracefully when entire modalities are absent. The fusion step has O(MK^2) complexity, compared with O(M^2 d^2) for cross-modal attention. The learned conflict metric also flags likely errors: reviewing 20% of samples captures 80% of misclassifications, which supports selective prediction in clinical and safety-critical systems.