Life sciences · Preprint
arXiv · November 6, 2026
No summary has been generated for this record yet. What follows is drawn from its source metadata only.
Preprint.
No findings were extractable from the material analysed.
Safety was not reported in the material analysed. Check the source before drawing any conclusion about harm.
The source did not state who this applies to in practice.
Graded across the dimensions that decide whether you should act, each from what the source actually supports. There is no single score, and where a dimension was not assessed it says so.
This record has not been graded across any dimension yet. Treat the label above as provisional and read the source.
What is missing. This record has no bottom line, key findings, reported figures, evidence dimensions. That is a gap in the analysis, not a judgement about the study.
Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements. Combining the two through agentic systems offers a route towards comprehensive radiology reporting, but published systems are tied to one modality or body part. We describe a radiology agentic framework that standardizes how an orchestrator calls modular tools to produce a structured report, and use it to measure what such a system can do with the tools from FDA-cleared radiology AI devices. Report generation is simulated on a large multi-modality report corpus, with the orchestrator given either a catalog of finding classes consolidated from the cleared devices, each available on the modalities it is cleared for, or an unlimited catalog in which any class can be requested, and planning either from the clinical indication or from the target report. Tool outputs are simulated from the reference report, so the comparison isolates tool availability and orchestration from tool error. With the cleared catalog and the indication alone, the orchestrator recovers under a third of the clinically actionable findings; recovery improves substantially with the unlimited catalog, and further when the plan is written from the target report. Attributing every missed finding to a cause shows that most are classes no cleared device offers for the study's modality, and that a third are classes or tools that were offered and not called. Adding the most frequently missing tools closes most of the gap to the unlimited catalog on held-out reports, whereas a smaller orchestrator with the unlimited catalog gives up the whole gain. Tool availability and effective orchestration are thus complementary constraints on comprehensive AI-assisted radiology reporting.